Maximum water pressure [bar]:
3
Heating capacity (at 80/60°C) [kW]:
3,7 - 24,0
Boiler useful efficiency at nominal load and 70°C average water temperature [%]:
98
Standard setpoint temperature [°C]:
40 - 80
Heating water and gas connection:
G3/4
Nitrogen dioxide emission level [mg/kWh]:
38
Degree of protection (IP rating):
IPX4D
Seasonal space heating energy efficiency class:
A
Reduced setpoint temperature [°C]:
25 - 55
Boiler weight [kg]:
33
Expansion vessel capacity [dm³]:
8
Heat exchanger material:
INOX stainless steel
Electrical consumption at full load elmax [kW]:
0,077
Type and voltage of electrical power supply:
~ 230 ±10%/ 50Hz V
Maximum CH operating temperature [°C]:
95
Overall dimensions (H x W x D) [mm]:
775 x 400 x 300
Sound power level LWA [dB]:
49
Electrical consumption at part load elmin [kW]:
0,059
Heating capacity (at 50/30°C) [kW]:
4,1 - 26,5
Domestic water connection:
G3/4
Connection to flue gas duct:
concentric Φ80/125; concentric Φ60/100 or 2 single Φ80
Useful efficiency η1 [%]:
99,7
Useful heat output at nominal heat output P4 (for modulating boilers arithmetic mean of max and min) [kW]:
24,3
Seasonal space heating energy efficiency ηs [%]:
95
Useful efficiency η4 [%]:
88,9
Standby power consumption PSB [kW]:
0,004
Pump head at zero flow [bar]:
0,6
Useful heat output at 30% nominal output P1 (for modulating boilers 30% arithmetic mean) [kW]:
8,0
Boiler useful efficiency at part load and 30°C return water temperature [%]:
108
Main photo
termet_euro_comfort_pp_01.jpg Download File
Product design pictures
energy_label_wkj5480.00.00.00_xx2t.png Download File
Product design pictures
termet-heat-gold-i-euro-comfort.png Download File
Declarations
doc_euro-comfort.pdf Download File
Leaflets and catalogues
termet_euro_comfort_leaflet_en_2025.pdf Download File
Leaflets and catalogues
catalog_termet_2026_en.pdf Download File
Leaflets and catalogues
datasheet_wkj5480.00.00.00_xx2t_en.pdf Download File